Vertiv Avocent ACS8000
Research advisory published Avocent ACS8000 terminal bridge exposes a potential unauthenticated root-command path
CVE-2026-65184 concerns command injection in the root-running wsserver terminal bridge. Client-controlled WebSocket values reach shell execution without adequate validation, and its public-key session path does not check for an appliance session. runZero reports that this could allow unauthenticated commands as root on the console server.[2][1]
Fix. No fixed firmware version is identified in the reviewed primary sources.[2][3]
Versions, remediation & sources
- Affected systems & conditions
- The CNA record lists Avocent ACS8000 firmware through 2.32.4. The reported testing used firmware analysis and a virtualized target running 2.32.4, not a fully validated physical appliance. The attacker must reach the appliance web port; the reported route requires no credentials or user interaction.[2][1][3]
- Remediation
- No fixed firmware version is identified in the reviewed primary sources. Our interim recommendation is to restrict web-management access to trusted administrative networks and check Vertiv for product-specific remediation. This reduces exposure; it is not a verified software fix.[2][3]
- Evidence at review time
- runZero explicitly says the finding has not yet been fully validated on a live device. Firmware analysis and virtualized testing are not evidence of exploitation in the wild. The reviewed sources do not report active attacks.[1][3]
- Related context
- The reported impact is control of the console server. That can expose the serial consoles and management paths it fronts, but does not establish automatic compromise of every downstream system. The October 26 disclosure is new; private discovery and vendor notification occurred earlier.[3][1]